Oklahoma City / Deer Creek
Deer Creek has 22 residents (give or take 21) (ACS 2020-2024 5-year, table B01003, https://data.census.gov/table/ACSDT5Y2024.B01003?g=160XX00US4019650, checked 2026-10-19), about 155 people per square mile.
Deer Creek is about 93 miles from the Census center point for Oklahoma City in a straight line and covers 0.142 square miles of land (Census 2024 Gazetteer internal points and land area, https://www2.census.gov/geo/docs/maps-data/data/gazetteer/2024_Gazetteer/, checked 2026-10-19).
The median Deer Creek home was built in 1938 (ACS 2020-2024 5-year, table B25035, https://data.census.gov/table/ACSDT5Y2024.B25035?g=160XX00US4019650, checked 2026-10-19) and the median home has 7.6 rooms (ACS 2020-2024 5-year, table B25018, https://data.census.gov/table/ACSDT5Y2024.B25018?g=160XX00US4019650, checked 2026-10-19).
No electric utility is on file for Deer Creek on this door yet, so this page does not name one; the name on the bill decides which rebate path applies.
Power Forward with PSO residential rebates (ASHP), run by PSO (Public Service Company of Oklahoma), is a live program for Oklahoma addresses and covers qualifying equipment at $500 per system (registry row 51 verified 2026-10-14, https://powerforwardwithpso.com/programs/heat-pump/, checked 2026-10-16); confirm eligibility for the Deer Creek address before counting it.
Median household income in Deer Creek is $56,000 (ACS 2020-2024 5-year, table B19013, https://data.census.gov/table/ACSDT5Y2024.B19013?g=160XX00US4019650, checked 2026-10-19); many state and utility heat pump rebate programs set higher incentive tiers for income-qualifying households, so the household income on the application, not the town median, decides which level applies.
Heating design temperature: 13F. Source: ENERGY STAR Design Temperature Limit Reference Guide (2019 Edition), Grant County row, 99% heating, PDF pages 97 to 100 of 141 (Revised 11/11/2020), https://www.energystar.gov/sites/default/files/Design%20Temperature%20Limit%20Reference%20Guide%20(2019%20Ed)%20-%20ENERGY%20STAR%20Single-Family%20New%20Homes_Rev11.pdf, fetched 2026-10-19, 99%.
That 13F figure is the Grant County cold-day number a Deer Creek heat pump is sized against, so ask the installer to show the system's heating output at 13F, not at the milder rating-label temperature.
Ask for the heat-loss calculation room by room; the median Deer Creek home has 7.6 rooms and was built around 1938, and the count of heads and the tonnage follow the rooms and the insulation, not the square footage.
The form on this page is the follow-up for Deer Creek. The public number is the number the contractor quotes from.
No local contractor is named on this door for Deer Creek yet. A request from this page goes to the first licensed shop that takes the door.